Rv onan Generator run and stopdie issue... To fix it simply make sure your oil is at the top of the add line on the dipstick yes thats it.. The oil sensor will shut down the generator if your oil is dirty or too full due to excessive bubbles.. I recommend an oil change and only add 1.5 quarts of oil. When your on a level surface your dipstick is inaccurate so it is important to fill oil to the top of the add line no higherwhile on a level service...This covers your gasoline generator for sure cummins onan 4000 5500 it dont matter all the same problem.. effected years are all years including 2019 mine is 2003 or 2005 fixed my problem.. I could only assume the oil sensor could go bad and cause the issue also. If it runs rough clean carburetor and change fuel filter..This is for the issue where your generator will start and run fine for a while the die again it may or may not start back up for a few minutes..If it runs great then dies this should fix your problem.. I have the onan 5500 generator and it would run for a few minutes then just die this happened several times... The oil needed changed but I drained oil out and added to the top of the add line and it took off for several hours until I shut it down to do oil change.. I changed the oil and put 1.5 quarts in and its ran for days like a champ yesterday remodeling the rv it ran a full load for about 15 hours.. I shut it off and it fired right back up.. please comment lets help eachother spread the word and fix things cheap or for free.. good luck..,